Skip to content

hw-comp-raid-redfish

Manage RAID volumes through the BMC's Redfish Storage service

Configures RAID through the BMC's Redfish Storage service using the redfish tool in drp-raid, for controllers that have no supported in-band vendor tool.

  • Each Redfish Storage resource that reports SupportedRAIDTypes and a Volumes collection is treated as a controller. Drive slots come from the Redfish location ordinal or numeric drive Id.
  • Cisco controllers use the Oem.Cisco.Spans volume format and clear foreign configuration on -clear.
  • Encryption is not supported, so raid-enable-encryption-tasks is empty.
  • The raid tasks run in the drpcli-runner context, which must reach the BMC over HTTPS. Credentials come from the machine's ipmi/* Params, and ipmi/mode must be redfish.

Example raid-target-config for a two drive mirror:

YAML
raid-target-config:
  - RaidLevel: raid1
    DiskCount: "2"
    Name: boot

Objects that Reference hw-comp-raid-redfish

Not used in current content packs

Objects used by hw-comp-raid-redfish