Parameter Precedence¶
What is the order precedence for parameters?
Solution¶
A parameter is looked up from the top to bottom of this list:
- Machine Parameter
- Machine Profile (or profiles in that profile).
- Stage Parameter
- Stage Profile
- Global Profile Parameter
- Global Profile Profile
- Parameter default.
This is handled by the template render engine. Values at the top of the list will replace values lower in the list.
You can see the state on a machine (except parameter defaults) by doing:
Note
It is possible that a Paramter can be defined as "Composed", which will NOT follow the Paramter Order of Precedence. The values will be built up from each of the levels of precedence and combined.
This is defined in the Template with the use of the
{{ .ComposeParam ... }}
and associated functions in the Architecture
Documentation Template (link
also below).
Additional Information¶
The drpcli
command line argument --aggregate
will not show any
Params default volues in the output.
To view what the default value of a param is you can find it in the UX by clicking on the Param navigation link on the left side of the screen, then searching for the param, then clicking on it. You can also use a simple drpcli command.
See Also¶
- Architecture Data Template documentation (Compose Param docs)
Versions¶